Envelope LabBuilding envelope lab
Change insulation thickness and continuity, then compare heat flow through two sections under the same indoor and outdoor conditions.
Inside surface temperature
Along the section heightConditions and model checksMethod · assumptions · sources +
Section and boundaries
Steady 2D conduction, 960 mm high, per 1 m depth, on a 32 × 48 finite-volume mesh aligned to layer interfaces. Inside and outside air connect through surface resistances; top and bottom are adiabatic. Arrow lengths are normalised for display.
Properties and scope
Properties are assumed values for experimenting and can be replaced with product data. The slab is a band through the wall; the window is equivalent glass and frame layers. Glass Ug includes the standard surface resistances 0.13 + 0.04. Solar gain, air leakage, moisture and real frame geometry are not modelled.
Checks and AI
Checked against the exact plane-wall solution, energy balance and grid convergence. The AI learns a 2D correction to an independent 1D resistance profile, with separate training and test sections. It predicts the temperature field only; performance numbers come from the solver. Everything runs in this browser.
A simplified 2D steady-state calculation. It is not a design, certification, code-compliance or condensation check, nor a prediction of energy savings. AI error figures compare against the solver on this section and are not probabilities.